Research on Hydrogen-Induced Delamination Cracking at Austenitic Stainless Steel Overlay Weld Sites

Literature Overview

This paper by Zeng Weihua, Han Huaiyue, Yin Fengchun, and Liao Juzhi, published in the Journal of Iron and Steel Research (1992, Vol. 4, Issue 2, pp. 67–76), presents a comprehensive study on hydrogen-induced delamination cracking at austenitic stainless steel overlay weld sites. The research employed high-pressure hydrogen charging tests and investigated the effects of various hydrogen exposure conditions and cooling cycles on delamination susceptibility. The work was conducted on 2½Cr-1Mo thick forged plates with three different strip and welding process overlay configurations. This research is of critical importance for the safe operation of hydrogenation reactors in the petrochemical industry.

Background and Motivation

Hydrogenation reactors in the petrochemical industry operate under high temperatures and pressures in the presence of hydrogen gas. The internal surfaces of these reactors are typically protected by an overlay layer of austenitic stainless steel to resist hydrogen attack and sulfidation. However, the overlay weld site is a critical area of concern because:

  1. The interface between the base metal and overlay layer is a potential site for hydrogen accumulation.
  2. The heat-affected zone (HAZ) of the base metal may have reduced resistance to hydrogen-induced cracking.
  3. The microstructural complexity of the overlay weld site creates multiple potential crack initiation sites.
  4. The thermal stresses from welding and operation can interact with hydrogen embrittlement to cause delayed cracking.

Hydrogen-Induced Cracking Mechanisms

Mechanism Description Susceptible Microstructure
Hydrogen blistering Hydrogen accumulation at inclusions and interfaces Austenitic stainless steel
Hydrogen-assisted cracking Hydrogen reduces cohesive strength Grain boundaries, carbide networks
Hydrogen embrittlement Hydrogen reduces ductility High-strength steels
Stress corrosion cracking Combined effect of stress and hydrogen Sensitized microstructures

Experimental Methodology

1. Test Specimen Preparation

Three types of overlay weld specimens were prepared on 2½Cr-1Mo thick forged plates:

Specimen Type Overlay Material Welding Process Strip Configuration
Type 1 309L Submerged arc strip welding Single strip
Type 2 309L Submerged arc strip welding Double strip
Type 3 347L Submerged arc strip welding Single strip

2. Hydrogen Charging Conditions

The high-pressure hydrogen charging test was conducted under the following conditions:

Parameter Value
Hydrogen pressure 10–20 MPa
Temperature 450 °C
Duration 48 hours
Cooling rate Controlled (air cooling, furnace cooling, or water quench)

3. Examination Methods

After hydrogen charging and cooling, the specimens were examined using:

Key Findings

1. Nature of Delamination Cracking

The study established that delamination cracking is a delayed phenomenon that occurs during or after cooling from the hydrogen charging temperature, not during the charging itself. This is a critical finding because it means that the cracking may not be detectable during the high-temperature exposure but only after cooling to room temperature.

2. Crack Morphology

The cracks exhibited the following characteristics:

Feature Description
Crack location Along coarse grain boundaries or carbide networks near the interface
Crack mode Intergranular
Crack direction Parallel to the interface (delamination)
Crack length 10–50 mm (variable)
Crack width 0.01–0.1 mm

3. Effect of Hydrogen Pressure

Increasing the hydrogen partial pressure significantly increased the delamination susceptibility:

Hydrogen Pressure (MPa) Delamination Rate (%) Average Crack Length (mm)
10 15 10–15
15 35 20–30
20 60 30–50

4. Effect of Cooling Rate

The cooling rate after hydrogen charging had a significant effect on delamination susceptibility:

Cooling Method Cooling Rate (°C/h) Delamination Rate (%)
Furnace cooling 5–10 10–15
Air cooling 50–100 30–40
Water quench > 500 50–70

The faster the cooling rate, the higher the delamination susceptibility. This is attributed to the trapping of hydrogen in the microstructure during rapid cooling, which increases the local hydrogen concentration at susceptible sites.

5. Effect of Overlay Material and Process

The different overlay configurations showed different susceptibility levels:

Specimen Type Delamination Rate (%) Susceptibility Ranking
Type 1 (309L, single strip) 25–35 Moderate
Type 2 (309L, double strip) 15–25 Lower
Type 3 (347L, single strip) 30–45 Higher

The double strip configuration showed lower susceptibility due to reduced dilution and a more favorable microstructure at the interface.

Engineering Implications

1. Material Selection

Based on the research findings, the following material selection guidelines are recommended:

Application Recommended Overlay Material Rationale
High-pressure hydrogen service (> 15 MPa) 309L with double strip Lowest delamination susceptibility
Moderate hydrogen service (10–15 MPa) 309L with single strip Acceptable susceptibility
Low-pressure hydrogen service (< 10 MPa) 309L or 347L Both acceptable

2. Process Optimization

The following process optimization measures are recommended:

3. Quality Control

A comprehensive quality control plan is essential for hydrogenation reactor overlay welding:

4. Operational Safety

The research findings have important implications for operational safety:

Key Questions and Reflections

The research raises several important questions for further investigation:

  1. Long-term behavior: The study was conducted under accelerated conditions. What is the long-term behavior of overlay welds under actual service conditions?
  2. Effect of impurities: The study did not address the effect of impurities such as sulfur, phosphorus, and nitrogen on delamination susceptibility.
  3. Mitigation strategies: Are there post-weld treatments or operational procedures that can mitigate the risk of delamination cracking?
  4. Modern materials: Have advances in overlay material development since 1992 reduced the susceptibility to hydrogen-induced delamination?

Study Insights and Implications

This research is of critical importance for the safe operation of hydrogenation reactors in the petrochemical industry. The identification of hydrogen-induced delamination as a delayed cracking phenomenon that occurs during cooling has significant implications for inspection and maintenance practices. The findings on the effects of hydrogen pressure, cooling rate, and overlay material selection provide a scientific basis for material and process selection decisions. For contemporary engineers, this research serves as a reminder of the importance of understanding the fundamental mechanisms of hydrogen-induced cracking and the need for comprehensive quality control and operational safety measures. The principles established in this research remain relevant today and continue to guide the design and operation of hydrogenation reactors worldwide.