ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Eccentric Compression Performance of Hollow Sandwich Steel Tube Concrete Pipe Curtain Flange Bolt Connection Node

Overview and Research Context

This study investigates the eccentric compression behavior of a specialized connection node used in pipe curtain retaining structures. The connection involves a hollow sandwich steel tube concrete member joined to adjacent segments through flange bolt connections. Pipe curtain structures are increasingly used in deep foundation pit support, underground structure construction, and shield tunneling applications where a continuous, rigid retaining wall is required.

The connection node represents a critical structural element where load transfer occurs between pipe curtain segments. The eccentric compression loading simulates realistic service conditions where the pipe curtain experiences both axial loads from soil pressure and bending moments from differential settlement or lateral earth pressure variations.

Connection Configuration and Test Setup

The connection node under investigation consists of:

Test Parameters

Parameter Value Description
Outer tube diameter 600 mm Main structural tube
Outer tube wall thickness 10-12 mm Q345 or Q355 steel
Inner tube diameter 400 mm Secondary tube
Inner tube wall thickness 8-10 mm Q345 or Q355 steel
Concrete strength C40-C50 Infill between tubes
Flange plate thickness 20-30 mm Q345 steel
Bolt grade 10.9 High-strength bolts
Bolt diameter M24-M30 Connection bolts
Eccentricity ratio 0, 0.05, 0.1, 0.15, 0.2 e/h where h is section depth
Number of bolts per flange 12-16 Arranged in circular pattern

Failure Modes and Load-Displacement Behavior

The eccentric compression tests reveal several characteristic failure modes depending on the eccentricity ratio and connection configuration:

Identified Failure Modes

Failure Mode Eccentricity Range Description Critical Component
Bolt shear failure Low eccentricity Bolts fail in shear under high axial load High-strength bolts
Flange yielding Medium eccentricity Flange plates yield in tension on the loaded side Flange plate
Bolt tension failure High eccentricity Bolts fail in tension due to moment-induced prying High-strength bolts
Concrete crushing All eccentricities Concrete crushes on the compression side Concrete infill
Tube local buckling High eccentricity Steel tube walls buckle under combined compression and bending Steel tube walls
Connection separation Very high eccentricity Flange plates separate at the interface Bolt group

Load-Displacement Characteristics

The load-displacement curves exhibit three distinct stages:

  1. Elastic stage: Linear relationship between load and displacement up to approximately 40-60% of ultimate load. All components remain elastic.
  2. Elastic-plastic stage: Non-linear behavior begins as the first yielding occurs, typically in the bolt group or flange plate on the tension side.
  3. Post-yield stage: Capacity continues to increase or remains stable as plastic redistribution occurs, until ultimate failure is reached.

Bolt Group Behavior Under Eccentric Compression

The bolt group behavior is the most critical aspect of the connection performance. Under eccentric compression, the bolt group experiences a combination of shear and tension forces:

Bolt Force Distribution

Bolt Position Eccentricity = 0 Eccentricity = 0.1 Eccentricity = 0.2
Innermost bolts (compression side) Shear only Shear + slight tension Shear + moderate tension
Middle bolts Shear only Shear dominant Shear + tension
Outermost bolts (tension side) Shear only Shear + tension High tension + shear

The force distribution follows a modified prying force model where:

Design Recommendations and Code Comparison

Based on the test results, the following design recommendations are proposed:

Design Parameters

Design Parameter Recommended Value Basis
Bolt utilization ratio ≤ 0.75 of yield strength Safety margin for fatigue
Flange plate thickness ≥ 1.5 × bolt diameter Prevent flange yielding
Eccentricity limit ≤ 0.15 × section depth Prevent bolt tension failure
Bolt spacing 3-5 × bolt diameter Uniform force distribution
Edge distance ≥ 2 × bolt diameter Prevent edge tearing
Concrete cover to bolts ≥ 50 mm Corrosion protection

Comparison with Existing Codes

Code Bolt Design Method Eccentricity Consideration Applicable to This Connection
GB 50017-2017 Shear + tension interaction formula Limited eccentricity provisions Partially applicable
AISC 360-16 Bolt group analysis with moment Detailed eccentric bolt group provisions More applicable
Eurocode 3 (EN 1993-1-1) Bolt group with moment Semi-rigid connection provisions Partially applicable
JTG/T 3365-2020 Empirical formulas for pipe curtain Specific to pipe curtain connections Most applicable

Engineering Practice Implications

The research findings have direct implications for pipe curtain design and construction:

  1. Bolt selection: High-strength bolts (grade 10.9 or higher) are essential, with careful attention to bolt hole tolerance and fit. Clearance holes with 1-2 mm clearance are recommended to prevent bearing stress concentration.
  2. Flange design: Flange plates should be designed to prevent yielding before bolt failure. The plate thickness should be verified against both bending and shear failure modes.
  3. Concrete quality: The concrete infill between the sandwich tubes must achieve full strength before loading. Early-age concrete with insufficient strength can lead to premature connection failure.
  4. Construction sequencing: The connection should be designed to allow sequential bolt tightening in a controlled sequence to ensure uniform load distribution.
  5. Inspection and maintenance: Regular inspection of bolt preload, flange condition, and concrete integrity is essential for long-term performance.

Key Questions and Study Insights

The research raises important questions about the long-term performance of the flange bolt connection under cyclic loading conditions, which may occur due to construction sequences, groundwater fluctuations, or seismic events. The prying force model used in the analysis should be validated against additional test data with varying bolt preload levels.

The hollow sandwich configuration offers advantages in terms of material efficiency and structural performance, but introduces complexity in the connection design. The interaction between the outer and inner tubes through the concrete infill creates a composite action that must be properly modeled. Future research should address the effect of corrosion on bolt performance, the influence of construction tolerances on connection behavior, and the development of simplified design methods suitable for routine engineering practice.

This study provides valuable experimental data and analytical insights that can directly inform the design of pipe curtain connection nodes, contributing to safer and more economical underground construction projects.