ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Axial Compression Performance of Steel Tube Recycled Aggregate Short Columns

Literature Overview

This experimental study by Wu Bo, Liu Wei, Liu Qiongxiang, and Xu Zhe (South China University of Technology, 2010), conducted under the State Key Laboratory of Subtropical Building Science, investigates the axial compression performance of steel tube confined recycled aggregate short columns. Through 17 experimental specimens tested at both 7-day and 28-day ages, the study compares the mechanical behavior of recycled aggregate CFST columns with conventional CFST columns and proposes a bearing capacity calculation formula based on comparison with existing design standards.

Research Background and Sustainability Context

The integration of recycled aggregate from demolished concrete into new structural members represents a significant sustainability strategy in construction engineering. China's rapid urbanization and infrastructure renewal have generated enormous volumes of construction and demolition waste, much of which consists of concrete rubble. The incorporation of recycled coarse aggregate (RCA) into concrete mixes offers a pathway for waste valorization while reducing natural resource consumption.

However, recycled aggregate concrete (RAC) typically exhibits lower mechanical properties compared to natural aggregate concrete (NAC) due to:

The steel tube confinement in CFST columns provides a natural solution to these concerns by:

Experimental Program Design

Parameter Specification Rationale
Number of specimens 17 total Sufficient statistical basis
Testing ages 7 days and 28 days Early-age and mature strength behavior
Recycled aggregate content 32%~35% by volume Moderate replacement level
Column type Short columns (slenderness ratio low) Isolate material effects from buckling
Loading condition Pure axial compression Fundamental material behavior
Comparison specimens Conventional CFST with natural aggregate Baseline for comparison

Experimental Results and Analysis

Strength Comparison

The key finding of this study is that steel tube recycled aggregate short columns incorporating 32%~35% recycled concrete aggregate exhibit axial compression performance comparable to fully cast conventional CFST short columns. This result is significant because it demonstrates that steel tube confinement effectively compensates for the inherent strength reduction associated with recycled aggregate.

Property Conventional CFST Recycled Aggregate CFST Ratio (Recycled/Conventional)
Peak axial strength Baseline 0.92~1.00× baseline Essentially equivalent
Initial stiffness Baseline 0.85~0.95×