Study Overview and Motivation

This 2025 publication by Dan Yu, Zhang Chunyu, She Haitao, Chen Hua, and Qin Shitao in Acta Materiae Compositae Sinica (Volume 42, Issue 12, pp. 7099-7112) addresses a timely and practically important problem: the structural retrofitting of existing reinforced concrete (RC) short columns using steel tubes filled with self-compacting recycled concrete (SCRC) and externally wrapped with CFRP sheets. The research is supported by the Guangxi Key R&D Program and the Nanning "Yongjiang Plan" Youth Talent Program, reflecting both the academic and policy-driven interest in green construction and structural strengthening in southern China.

The study is significant from a metallurgical and pipe engineering standpoint because it investigates how the combination of steel tube confinement, recycled aggregate concrete, and CFRP wrapping interacts to enhance the residual load capacity, stiffness, and ductility of deteriorated RC columns. The use of recycled coarse aggregate in the infill concrete introduces additional material variability that must be accounted for in design.

Experimental Programme and Key Parameters

A total of 12 specimens were tested: one unreinforced RC short column as a reference, and eleven reinforced specimens with varying parameters. The test matrix included:

Variable Parameter Range of Values Purpose
Concrete strength of original RC column Multiple levels Represent different degradation states
Steel tube wall thickness Multiple levels Vary confinement pressure
Recycled coarse aggregate replacement ratio Multiple levels Assess sustainability impact
CFRP sheet layers Multiple levels Vary external confinement
Post-retrofit cross-section diameter Multiple levels Assess geometric effects

The specimens were subjected to monotonic axial compression loading until failure. Load-displacement curves were recorded throughout, and the full failure process was observed and documented.

Core Technical Results

Load Capacity Enhancement

The ultimate stress enhancement ratio (the ratio of the reinforced column's ultimate stress to the unreinforced column's ultimate stress) ranged from 1.14 to 2.30. This represents a substantial improvement, particularly for columns with lower original concrete strength. The enhancement is attributed to the combined confinement effect of the steel tube and CFRP on the SCRC infill, which in turn provides enhanced lateral support to the original RC core.

Effect of Individual Parameters

Ductility and Stiffness

All reinforced specimens exhibited ductile failure modes, in contrast to the brittle failure of the unreinforced reference column. The initial axial stiffness was significantly increased by the retrofitting, primarily due to the high elastic modulus of the steel tube. The ductility improvement is attributed to the steel tube's ability to sustain large inelastic deformations after yielding, combined with the CFRP's contribution to lateral confinement at the ultimate load stage.

Finite Element Analysis and Model Validation

The authors developed ABAQUS finite element models to complement the experimental programme and extend the parametric study beyond the physical specimen limits. The models incorporated:

The finite element results showed good agreement with experimental data, validating the modelling approach. Extended parametric studies revealed that:

Proposed Analytical Model

Based on the limit equilibrium method, the authors proposed an axial compressive load capacity formula for the retrofitted columns. The formula incorporates:

  1. The contribution of the original RC column (reduced by a degradation factor).
  2. The contribution of the steel tube-SCRC composite annulus, accounting for the confining pressure from both the steel tube and CFRP.
  3. The recycled aggregate safety factor to adjust for the reduced strength of recycled concrete.
  4. The material utilisation coefficient to account for incomplete stress transfer at interfaces.

The average error between the analytical predictions and experimental results was within 5%, which is excellent for a composite column system with multiple interacting materials.

Welding and Fabrication Quality Considerations

From the perspective of steel pipe fabrication and welding engineering, the following quality control aspects are critical for the successful implementation of this retrofitting system:

Steel Tube Welding Quality

The steel tube used for the retrofitting annulus is typically a welded steel pipe. The quality of the longitudinal weld is paramount because:

CFRP Bonding Quality

The CFRP sheets must be bonded to the outer surface of the steel tube with structural epoxy adhesive. Key quality control points include:

Sustainability and Engineering Practice

The use of self-compacting recycled concrete in this retrofitting system represents a meaningful contribution to sustainable construction. Recycled coarse aggregates derived from demolished concrete can be used in structural applications when properly characterised and quality-controlled. The self-compacting property of the concrete ensures adequate filling of the annular space between the steel tube and the original RC column without the need for vibration, which is particularly advantageous in congested construction sites.

However, engineers must be aware that recycled aggregates introduce additional variability in concrete properties. The ITZ between recycled aggregates and the cement paste is weaker and more permeable than the ITZ in conventional concrete. This can affect long-term durability, particularly in environments where chloride ingress or carbonation is a concern. Additional impermeability measures (such as crystalline admixtures or surface treatments) may be warranted.

Reflections on the Analytical Model

The proposed analytical model, with an average error within 5%, represents a significant advance in the predictive capability for this type of composite retrofitting system. The introduction of the recycled aggregate safety factor and material utilisation coefficient is a pragmatic approach that acknowledges the inherent variability in recycled materials. In my experience with composite structural systems, such empirical coefficients are essential for bridging the gap between idealised analytical models and the messy reality of construction materials.

That said, the model is based on monotonic loading and short-term behaviour. For long-term serviceability, the following factors should be considered:

Conclusion

This study provides a comprehensive experimental and analytical framework for the structural retrofitting of RC short columns using steel tube self-compacting recycled concrete with CFRP wrapping. The dual-confinement mechanism of the steel tube and CFRP, combined with the sustainability benefits of recycled aggregates, makes this system a promising solution for strengthening deteriorated concrete structures. The analytical model, validated with an average error within 5%, offers a practical design tool. Engineers implementing this system must pay careful attention to the welding quality of the steel tube, the bonding quality of the CFRP, and the long-term durability of the recycled concrete infill. The integration of green construction principles with proven structural engineering methods represents a constructive path forward for the built environment.