Seismic Test of Prefabricated Connection Between Concrete-Filled Steel Tube Column and Steel Beam

Literature Overview

This paper by Wang Qingjie from Shenyang Jianzhu University School of Science, and Zhang Yannian, Xu Chunyi, Zhao Jinfeng, Tian Peng, and Yang Guang from Shenyang Jianzhu University School of Civil Engineering, published in the Journal of Shenyang University of Technology (Volume 36, Issue 3, 2014), presents low-cycle reversed loading tests on a novel prefabricated connection between a concrete-filled steel tube (CFST) column and an H-section steel beam. The research was supported by the "Twelfth Five-Year Plan" National Science and Technology Support Program (2012BAJ16B05), the Liaoning Provincial Department of Education Science Research Program (L2013231), the Liaoning Provincial Outstanding Young Scholar Growth Program (LJQ2011061), and the Shenyang Science and Technology Program (F12-216-8-00).

Connection Design and Test Configuration

The proposed prefabricated connection utilizes a ring plate (annular plate) as the primary load transfer element between the CFST column and the steel beam. The connection design is intended to be simple, constructible, and capable of transferring both flexural and shear forces effectively. Multiple specimens with varying parameters were tested to investigate the influence of different design variables on the seismic performance.

Specimen Parameters and Test Results

Parameter Variation Effect on Bearing Capacity
Axial compression ratio Increasing Decreases capacity
Ring plate width Increasing Increases capacity
Ring plate shape Square vs. Circular Square is higher
Bearing plate presence With vs. Without With plate is higher

All specimens underwent three distinct stages: elastic, plastic, and ultimate failure. The failure consistently occurred at the connection between the ring plate and the steel beam flange, indicating that this interface is the critical detail requiring careful design and fabrication.

Seismic Performance Characteristics

The low-cycle reversed loading tests revealed that the proposed connection exhibited good ductility and energy dissipation capacity. The hysteresis loops were full and well-formed, indicating stable energy dissipation throughout the loading cycles. The stiffness degradation was gradual, and the specimens maintained significant load-carrying capacity even after large inelastic deformations.

The influence of the axial compression ratio was found to be significant, with higher axial loads leading to reduced bearing capacity. This is consistent with the general behavior of composite connections, where axial compression reduces the available flexural capacity. The ring plate width was found to have a positive effect on bearing capacity, as a wider plate provides a larger load transfer area and reduces stress concentrations at the beam-flange-to-ring-plate interface.

Comparative Analysis of Ring Plate Geometries

Ring Plate Shape Bearing Capacity Ductility Fabrication Complexity
Circular Baseline Good Moderate
Square Higher than circular Good Lower

The square ring plate was found to have higher bearing capacity than the circular ring plate, likely due to the more direct load transfer path along the beam flange direction. The bearing plate, when present, provided additional support to the beam flange, reducing local yielding and increasing the overall connection capacity.

Fabrication and Welding Quality Requirements

The prefabricated connection requires high-quality welding between the ring plate and the steel beam flange, as this is the critical failure location. The weld design must ensure full penetration to achieve the required load transfer capacity. The following welding quality requirements are critical:

  1. Weld type selection: Fillet welds may be sufficient for lower capacity requirements, but groove welds with full penetration are recommended for seismic applications where ductility is essential.
  2. Weld inspection: All welds must be inspected using non-destructive testing methods such as ultrasonic testing (UT) or radiographic testing (RT) to detect internal defects such as lack of fusion, porosity, and slag inclusion.
  3. Heat-affected zone control: The HAZ of the welds must be characterized to ensure adequate toughness, particularly for high-strength steels where the HAZ may be susceptible to microcracking under cyclic loading.
  4. Distortion control: Welding distortion must be controlled to maintain the geometric alignment of the connection components. Excessive distortion can lead to misalignment and reduced load transfer efficiency.

Engineering Practice Recommendations

The proposed prefabricated connection offers several advantages for practical application:

For engineering practice, the following recommendations are proposed: the axial compression ratio should be limited to ensure adequate ductility; the ring plate width should be optimized to balance bearing capacity and fabrication cost; square ring plates should be preferred over circular ones where feasible; and bearing plates should be included to enhance the connection capacity.

Study Insights

This research contributes a practical and efficient connection solution for CFST column-to-steel beam connections in seismic regions. The prefabricated design philosophy aligns with modern construction trends toward prefabrication and modular construction, which offer advantages in quality control, construction speed, and labor efficiency. The identification of the ring plate-to-beam flange interface as the critical failure location provides valuable guidance for detailed design and quality control. Engineers should pay particular attention to the welding quality at this interface, as weld defects can significantly reduce the seismic performance of the connection.