ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Temperature Field Measurement of Steel Tube Concrete Truss Arch Under Solar Radiation

Literature Overview

The paper by Chen Baochun and Liu Zhenyu, published in China Journal of Highway and Transport in 2011, presents field measurement results of temperature distribution in the chords of a steel tube concrete truss arch bridge under solar radiation. This research addresses a practical engineering problem: the thermal effects of solar radiation on steel tube concrete (SRC) truss arch structures. The authors installed temperature measurement points on the arch rib cross-sections and deployed a small weather station to collect meteorological data. The study analyzes the temperature distribution patterns in the upper and lower chord tubes and evaluates the temperature-induced stresses using finite element analysis. The findings provide valuable guidance for thermal design of SRC truss arch bridges.

Core Technical Findings

The research reveals several important patterns in the temperature distribution of SRC truss arch chords under solar radiation:

Temperature Distribution Pattern Observation Engineering Implication
Parallel to sun rise/set direction Upper and lower chord temperatures are similar Thermal gradient between chords is small
Perpendicular to sun rise/set direction Left and right chord temperatures are similar Symmetric thermal response in transverse direction
Chord tube temperature profile Similar to single circular tube Simplified thermal model is applicable
Inter-chord temperature difference Small temperature difference between chords Temperature stresses between chords are negligible
Chord-chord tube temperature difference Small difference between chord and web tubes Thermal stresses from this difference are insignificant

The key conclusion of this research is that the temperature distribution and average temperature of each chord tube in the truss arch are similar to those of a single circular tube. This finding simplifies the thermal analysis significantly, as engineers can apply established thermal models for single SRC tubes to each chord tube in the truss arch configuration. Furthermore, the temperature difference between different chord tubes is small, and the resulting temperature stresses are also small, suggesting that thermal effects between chords can be neglected in practical calculations.

Temperature Field Analysis Methodology

The field measurement approach employed in this study involves:

  1. Temperature measurement point layout: Thermocouples are installed at strategic locations on the arch rib cross-sections to capture the temperature distribution across the chord tube walls and within the concrete core.
  2. Meteorological data collection: A small weather station is deployed near the bridge to record ambient temperature, solar radiation intensity, wind speed, and other relevant meteorological parameters.
  3. Data correlation: The measured temperature data is correlated with meteorological parameters to identify the dominant factors influencing the temperature distribution.
  4. Finite element thermal analysis: A finite element model is developed to calculate the average temperature of each chord tube and the resulting temperature stresses.

The temperature distribution in the chord tubes under solar radiation can be understood through the following mechanisms:

Engineering Practice Implications

The findings of this research have direct implications for the thermal design of SRC truss arch bridges:

  1. Simplified thermal modeling: The temperature distribution in each chord tube can be modeled using established single-tube thermal models, avoiding the need for complex three-dimensional thermal analysis of the entire truss arch.
  2. Negligible inter-chord thermal stresses: The small temperature differences between chord tubes mean that thermal stresses arising from differential expansion between chords are insignificant and can be neglected in structural design.
  3. Chord-web thermal interaction: The temperature difference between chord tubes and web members is also small, meaning that thermal stresses from this interaction are negligible in practical calculations.
  4. Thermal design focus: The primary thermal design consideration should be the temperature gradient across the chord tube cross-section, which induces bending stresses in the tube wall.

Key Questions and Reflections

While the findings of this research provide valuable practical guidance, several questions merit further consideration:

Study Insights and Reference Value

This research provides practical, measurement-based guidance for the thermal design of SRC truss arch bridges. The key insight is that the thermal behavior of truss arch chords under solar radiation is largely predictable from single-tube thermal models, and the inter-chord thermal effects are negligible. This simplification is valuable for practical engineering design, as it reduces the complexity of thermal analysis while maintaining adequate accuracy. For bridge engineers, this research supports the adoption of simplified thermal design approaches for SRC truss arch structures, provided that the temperature gradient across individual chord tubes is properly accounted for.