ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Failure Analysis of Dissimilar Steel Tube Joints in Boiler Superheaters

Literature Overview

This failure analysis paper by Meng Qingsen, Luo Guangmin, Liang Jun, and Xue Jin (2000, Materials Science and Technology, Vol. 8, No. 2, pp. 101–104) investigates the cracking failure of dissimilar steel welded joints in the superheater tubes of the Shentou II Power Plant. Funded by the Shanxi Provincial Natural Science Foundation (Grant No. 9801034), this case study provides valuable insights into high-temperature failure mechanisms in power plant components—a critical concern for boiler integrity management.

Core Technical Content

Failure History

Event Description
Initial failure Cracking along the heat-resistant steel HAZ after approximately 4×10⁴ hours of high-temperature operation
Repair Manual arc welding (SMAW) repair of the crack
Secondary failure Crack re-appeared after a period of post-repair operation

Failure Analysis Methodology

The investigation employed:

Phase 1 Failure: Creep Failure

The initial failure was identified as creep failure in the heat-resistant steel heat-affected zone (HAZ). Evidence supporting this conclusion:

Microstructural Feature Significance
Pearlite spheroidization Long-term high-temperature exposure causing ferrite-carbide structure transformation
Carbide agglomeration Coarsening of M₂₃C₆ and other carbides reducing solid solution strengthening
Carbon migration Carbon depletion in the HAZ and enrichment in the weld metal

These features are classic indicators of creep damage in ferritic-martensitic steels at elevated temperatures. The HAZ is particularly vulnerable because the welding thermal cycle creates a microstructural gradient with reduced creep resistance.

Phase 2 Failure: Stress Corrosion Cracking (SCC)

The secondary failure following SMAW repair was attributed to stress corrosion cracking. Contributing factors:

  1. Residual stress: Introduced by the repair welding process, creating tensile stress concentrations
  2. Corrosive environment: Water vapor containing chloride ions (Cl⁻) in the superheater environment
  3. Weld defects: Pre-existing or repair-induced defects creating stress concentration sites
  4. Microstructural susceptibility: The HAZ microstructure providing preferential crack initiation sites

The combination of tensile stress, chloride-containing water vapor, and susceptible microstructure created the conditions for chloride-induced SCC.

Failure Mechanism Summary

Failure Phase Mechanism Location Contributing Factors
Initial (Phase 1) Creep Heat-resistant steel HAZ Long-term high-temperature exposure, microstructural degradation
Secondary (Phase 2) Stress Corrosion Cracking Near repair weld Residual stress, Cl⁻ environment, weld defects

Engineering Countermeasures

Welding Process Improvement

The recommended improvement involves:

Aspect Original Recommended
Filler metal Matching carbon steel electrode Nickel-based filler wire
Process SMAW (Manual arc welding) TIG (GTAW) welding
Joint design Direct butt joint Transition joint with nickel-based overlay
Post-weld treatment None specified Stress relief annealing

Why Nickel-Based Filler Metal?

Nickel-based alloys (such as Inconel 625 or equivalent) offer several advantages for dissimilar steel joints in high-temperature service:

Quality Control for Dissimilar Steel Welds

Based on this failure case, the following quality control measures should be implemented:

  1. Pre-weld inspection: Verify base metal condition, ensure no pre-existing cracks or surface damage
  2. Weld procedure qualification: Use WPS/PQR qualified for the specific dissimilar metal combination
  3. Heat input control: Minimize heat input to reduce the extent of the vulnerable HAZ
  4. Post-weld heat treatment: Stress relief to reduce residual stresses
  5. Non-destructive testing: 100% UT or RT inspection of dissimilar joints
  6. Periodic in-service inspection: Regular UT examination during operation to detect early-stage cracking

Study Insights and Reflections

This failure analysis case is a textbook example of how multiple failure mechanisms can interact in complex ways. The initial creep failure was not unexpected given the service conditions and material selection, but the secondary SCC failure following repair illustrates a critical lesson: repair welding must be designed with the same rigor as the original fabrication.

The use of SMAW for the repair was problematic for several reasons:

The recommendation to use TIG welding with nickel-based filler metal represents a best-practice approach for dissimilar steel joints in high-temperature service. This principle applies broadly to power plant maintenance and repair activities.

From a metallurgical perspective, the carbon migration phenomenon observed in this case is a fundamental concern for all ferritic-martensitic steel weldments in high-temperature service. The carbon-depleted zone in the HAZ and the carbon-enriched zone in the weld metal create regions of reduced strength and altered microstructure that are inherently more susceptible to creep and corrosion damage. Understanding and mitigating this phenomenon through proper material selection and welding procedure design is essential for reliable long-term service.