ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Dynamic Response of Double Tube Concrete Filled Steel Tube Columns Under Coupled High Temperature and Impact Loading

Literature Overview

The paper by Kong Xiangqing, Zhang Huiling, Zhang Wenping, Fu Ying, and Zhang Wenjiao, published in Journal of Vibration and Shock in 2023 (Vol. 42, Issue 10, pp. 92-102), presents a finite element study on the dynamic response of concrete-filled double-tube (CFDT) columns under the coupled action of high temperature and lateral impact. The research is supported by the National Natural Science Foundation of China (Grant No. 51479168) and the Liaoning Provincial Department of Education Basic Research Project (LJK20626). The authors develop a finite element model using ABAQUS that accounts for material temperature softening, strain rate strengthening, and axial force effects, validated against fire test and lateral impact test data. Parametric studies investigate the influence of cross-section geometry, axial compression ratio, impact velocity, and concrete strength on the impact resistance performance at elevated temperatures.

Core Technical Content

Finite Element Model Development

The finite element model captures the complex mechanical behavior of CFDT columns through several key material models:

The model is validated in two stages: first against fire test data to verify the thermal and structural behavior under elevated temperatures, and then against lateral impact test data at ambient temperature to confirm the dynamic response prediction capability.

Dynamic Response Analysis

The study investigates the impact response through several key metrics:

Response Parameter Description Key Finding
Impact force Peak and plateau force during impact Decreases with increasing temperature
Mid-span displacement Maximum deflection at impact point Increases with temperature
Load distribution Spatial distribution of impact force Concentrates near impact point
Damage evolution Progressive damage accumulation Accelerates at high temperatures

The research reveals that CFDT columns exhibit bending-dominated failure under lateral impact, with the failure mode remaining consistent across the temperature range studied. The fire resistance limit of CFDT columns is found to be 2.1 times that of conventional single-tube CFST columns, demonstrating the significant benefit of the double-tube configuration.

Parametric Study Results

The parametric analysis provides valuable quantitative insights:

Parameter Variation Range Effect on Impact Force at 800°C
Axial compression ratio 0 to 0.6 32.4% decrease in plateau force
Concrete strength 40 to 60 MPa 22.8% increase in plateau force
Impact velocity Various Higher velocity reduces energy absorption per unit displacement
Cross-section geometry Various Outer tube dimensions have greater influence than inner tube

The finding that axial force has a detrimental effect on impact resistance is particularly significant for engineering practice. Columns subjected to high axial loads, such as those in multi-story buildings or heavy industrial structures, are more vulnerable to impact damage at elevated temperatures. The 32.4 percent reduction in impact force plateau value when the axial compression ratio increases from 0 to 0.6 at 800°C represents a substantial degradation that must be accounted for in design.

The positive effect of concrete strength is also noteworthy, with a 22.8 percent improvement in impact force plateau value when concrete strength increases from 40 to 60 MPa at 800°C. This suggests that using higher-strength concrete in CFDT columns can partially compensate for the temperature-induced degradation of impact resistance.

Welding and Fabrication Considerations

The CFDT column configuration involves two concentric steel tubes with concrete filling the annular space between them. This configuration presents specific challenges for fabrication and welding:

The welding procedure must account for the thermal effects of welding on the already temperature-damaged steel tubes. In fire-exposed scenarios, the residual strength of the steel tubes after fire cooling must be assessed before any repair welding is performed.

Engineering Practice Implications

The research provides critical insights for the design of CFDT columns in applications where fire and impact resistance are both required, such as in:

The finding that CFDT columns offer 2.1 times the fire resistance of conventional CFST columns is a compelling argument for their use in fire-prone environments. The double-tube configuration provides additional thermal insulation through the air gap or concrete layer between the tubes, slowing the temperature rise in the inner tube and preserving structural integrity for longer durations.

The parametric results guide design optimization:

Key Questions and Reflections

Several important questions emerge from this research. First, the study focuses on lateral impact, but real-world scenarios may involve oblique or multi-directional impacts that require further investigation. The interaction between impact direction and the double-tube configuration may produce different damage patterns that affect structural integrity differently.

Second, the study assumes a uniform temperature distribution across the column cross-section, which may not be realistic in practical fire scenarios where temperature gradients develop due to differential heat exposure. The thermal gradient effects on the steel tubes and concrete may create additional stresses that compound the impact damage.

Third, the long-term behavior of CFDT columns after fire exposure and impact damage is not addressed. The residual strength, fatigue life, and corrosion resistance of damaged columns are critical considerations for post-event assessment and repair decisions.

Another consideration is the scalability of the findings. The study focuses on specific column dimensions and material properties, and the applicability to larger-scale columns or different material combinations requires further investigation. The strain rate effects may vary with scale due to different strain rate distributions in larger cross-sections.

Study Insights and Implications

This research makes a significant contribution to the understanding of CFDT column behavior under coupled fire and impact loading, providing quantitative data that can directly inform engineering design. The finite element model, validated against experimental data, offers a reliable predictive tool for assessing the impact resistance of CFDT columns at elevated temperatures. The parametric study provides actionable design guidance, highlighting the importance of axial compression ratio control and concrete strength optimization. For engineers involved in steel pipe manufacturing and welding, the implications are that the quality of fabrication and welding directly affects the fire and impact performance of CFDT columns, and that the double-tube configuration, while offering superior fire resistance, requires careful attention to concentricity control and tie weld quality. The research also underscores the need for continued investigation into the long-term behavior of fire-damaged CFDT columns and the development of repair and retrofit strategies for post-event structural assessment.