ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Pushover Test Study on Masonry Structures Constrained by Steel Tube Bundle Shear Walls

Literature Overview

Chen Yong et al. (2020), published in the Journal of Zhejiang University (Engineering Science), present experimental and analytical studies on masonry structures reinforced with steel tube bundle shear walls as edge members. The research was funded by the National Key R&D Program and addresses the seismic retrofitting and new construction challenges for masonry buildings through innovative composite wall systems.

Core Technical Points

Steel Tube Bundle Shear Wall Configuration

The steel tube bundle shear wall system comprises multiple steel tubes bundled together with concrete infill, creating a composite shear wall element that provides lateral resistance while constraining adjacent masonry panels. This configuration offers advantages over conventional reinforced concrete shear walls in terms of construction speed, material efficiency, and compatibility with masonry construction methods.

Pushover Test Results

Test Parameter Specimen 1 (Edge Member Type A) Specimen 2 (Edge Member Type B)
Peak lateral load capacity Higher Lower
Displacement at peak load Moderate Higher
Failure mode Masonry debonding followed by diagonal cracking Progressive diagonal cracking
Energy dissipation capacity Moderate Higher
Ductility ratio Lower Higher

Equivalent Diagonal Strut Model

The study validates two simplified models for representing masonry panel behavior:

  1. Single strut model: Considers one compressive diagonal strut per panel. Simple but underestimates capacity and overestimates stiffness in early loading stages.
  2. Three-strut model: Distributes the compressive force across three diagonal struts (two compression struts and one tension strut equivalent). Provides better correlation with test results when parameters are properly calibrated.
Model Parameter Single Strut Three Strut (Recommended)
Effective strut width Full panel width Fraction of panel width
Strain compatibility Poor Good
Load-displacement correlation Underestimates initial stiffness Accurate throughout loading range
Applicable loading range Elastic to early inelastic Full inelastic range

Engineering Practice Considerations

Welding and Steel Tube Specifications

The steel tube bundle shear wall involves critical welding operations:

Masonry-Steel Interface Behavior

The pushover test reveals a critical failure sequence:

  1. Initial debonding between masonry panel and steel tube bundle edge members
  2. Formation of diagonal compression struts within the masonry panel
  3. Progressive cracking and crushing of masonry along the diagonal compression zone
  4. Final failure by masonry crushing and steel tube local buckling

This sequence indicates that the masonry-steel interface bond is the weakest link in the composite system. Proper detailing of the interface (mechanical interlock, chemical adhesive, or grout) is essential for achieving the full composite action predicted by the three-strut model.

Key Questions and Reflections

The research raises important questions about the practical implementation of steel tube bundle shear walls in masonry construction:

Study Insights and Outlook

This research demonstrates that steel tube bundle shear walls can effectively enhance the lateral load resistance of masonry structures while maintaining compatibility with traditional masonry construction methods. The three-strut model provides a practical analytical tool for design engineers. Future development should focus on standardized connection details, construction quality control procedures, and code provisions to facilitate widespread adoption in seismic retrofitting and new construction applications.