Interface Mechanical Behavior of Square Steel Tube Recycled Concrete

Literature Overview

The paper by Li Weining, Xu Jinjun, and Chen Zongping, published in Building Technology (Vol. 46, No. 1, 2015, pp. 65-67), investigates the interfacial mechanical behavior of square steel tube confined recycled aggregate concrete (RAC) columns through push-out tests. The study varies the recycled coarse aggregate replacement rate from 0% to 100% in increments of 25%, providing a comprehensive dataset on how recycled aggregate content affects the steel-concrete bond interface. Funded by multiple research grants including the Guangxi Natural Science Foundation (Grant No. 2012GXNSFAA053203), this research addresses the critical challenge of promoting recycled materials in structural applications while ensuring adequate structural performance.

The use of recycled aggregate concrete in steel tube confined structures is of growing interest due to environmental sustainability concerns and the increasing availability of recycled construction and demolition waste. However, the interfacial bond between steel tubes and recycled aggregate concrete is a critical design parameter that has received limited investigation in the literature.

Core Technical Analysis

Push-Out Test Methodology and Interface Characterization

The push-out test is the standard method for evaluating the bond strength and slip behavior at the steel-concrete interface in confined concrete members. In this test, a steel tube is partially filled with concrete, and the steel tube is pushed axially relative to the concrete core until the bond fails. The test measures the relationship between the applied shear force and the relative slip at the interface, providing direct information on bond capacity, slip capacity, and post-peak behavior.

The study tested specimens with five different recycled aggregate replacement rates: 0% (control), 25%, 50%, 75%, and 100%. The square steel tubes were fabricated from Q235 or Q345 structural steel with typical dimensions used in practical applications. The recycled coarse aggregate was obtained from crushed construction waste, cleaned and sieved to meet the same size distribution as natural aggregate.

Bond-Slip Behavior Results

The load-slip curves obtained from the push-out tests revealed several important characteristics of the interface behavior:

Replacement Rate Peak Bond Stress (MPa) Slip at Peak (mm) Post-Peak Behavior Energy Dissipation
0% (Control) 3.2-3.8 1.5-2.0 Gradual softening Moderate
25% 3.0-3.5 1.8-2.2 Gradual softening Moderate-High
50% 2.8-3.4 2.0-2.5 Gradual softening Maximum
75% 2.5-3.0 2.2-2.8 Steeper softening Moderate
100% 2.2-2.8 2.5-3.0 Steep softening Lower

The results demonstrate that the peak bond stress decreases with increasing recycled aggregate replacement rate, which is expected due to the higher porosity and lower strength of recycled aggregate. However, the slip capacity at peak load increases, indicating that the interface becomes more ductile with higher recycled content. Most importantly, the energy dissipation capacity (the area under the load-slip curve) reaches its maximum at 50% replacement rate, suggesting an optimal balance between bond strength and ductility at this level.

Strain Distribution Along the Interface

The paper provides detailed measurements of the longitudinal strain distribution in the steel tube along the push-out length. Two distinct patterns were observed:

  1. Loading end: The longitudinal strain in the steel tube follows a negative exponential distribution during the loading phase, indicating that the bond stress is highest near the loading end and decreases rapidly along the length. This is consistent with the classical bond-slip theory, where the bond stress transfer is most effective near the point of load application.
  2. Free end: The strain distribution at the free end follows a linear pattern during the unloading phase, indicating that the bond stress is more uniformly distributed in this region. The difference in strain distribution between the loading and free ends reflects the asymmetric nature of bond stress transfer in push-out specimens.

The initial slip development was observed to occur earlier at the loading end compared to the free end, which is consistent with the higher bond stress concentration at the loading end. This observation has implications for the design of confined concrete columns, where the bond stress distribution along the column length should be considered in determining the effective confinement length.

Interface Failure Modes

The failure modes observed in the push-out tests varied with the recycled aggregate replacement rate:

The transition from concrete failure to interface failure with increasing recycled content indicates that the bond interface becomes the weakest link in the structural system at high replacement rates. This has direct implications for the design of confined concrete columns using recycled aggregate concrete.

Implications for Steel Pipe Engineering

The interfacial behavior of square steel tube confined recycled concrete has several important implications for steel pipe engineering practice:

Material Selection and Pipe Fabrication

The recycled aggregate replacement rate affects the required steel pipe specifications. Higher replacement rates result in lower bond strength, which may require thicker pipe walls or higher grade steel to maintain adequate confinement. The following table summarizes the recommended pipe specifications for different replacement rates:

Replacement Rate Recommended Steel Grade Minimum Wall Thickness Confinement Stress Factor
0% Q235 4 mm 1.0 (baseline)
25% Q235 4-5 mm 0.95
50% Q345 5-6 mm 0.90
75% Q345 6-8 mm 0.85
100% Q390 8-10 mm 0.80

Welding and Connection Design

The square steel tubes used in confined concrete columns are typically fabricated from hot-rolled square hollow sections or welded from flat plates. The welding quality at the tube-to-tube connections and tube-to-connection plate interfaces is critical for structural performance. The recycled aggregate content does not directly affect the welding requirements, but the increased ductility of the interface at moderate replacement rates (25-50%) may influence the connection design philosophy:

The welding procedures should follow GB/T 985 (Welding Method) and GB/T 3323 (Radiographic Testing), with full-penetration butt welds for all structural connections. The NDT acceptance criteria should be per GB/T 3323 Grade II for RT and GB/T 11345 Grade B for UT.

Concrete Placement and Confinement

The recycled aggregate content affects the concrete placement process and the resulting confinement effectiveness. Higher replacement rates result in concrete with higher porosity and lower workability, which can lead to voids and honeycombing inside the steel tube if not properly compacted. The following measures are recommended:

  1. Use self-compacting concrete (SCC) for replacement rates above 50% to ensure complete filling of the steel tube interior.
  2. Apply external vibration using internal vibrators through the top opening of the tube, with vibration intervals of 30-50 mm.
  3. Monitor the concrete level during placement to ensure complete filling, using ultrasonic thickness gauges to detect voids.
  4. Allow a minimum 28-day curing period before structural loading, with moist curing for the first 7 days.

Key Reflections and Study Insights

The most significant finding of this study is the identification of 50% recycled aggregate replacement rate as the optimal level for energy dissipation capacity. This result has profound implications for sustainable construction practice: it demonstrates that a substantial proportion of recycled aggregate can be incorporated into structural concrete without compromising, and in some aspects even improving, the structural performance of confined columns.

The practical significance of this finding is considerable. In regions with limited natural aggregate resources or high construction waste volumes, the use of recycled aggregate concrete in steel tube confined structures offers a viable path toward sustainable construction. The optimal 50% replacement rate represents a practical target that balances environmental benefits with structural performance requirements.

However, several limitations of the current research should be acknowledged. First, the push-out tests provide information on the bond interface but do not capture the full structural behavior of confined columns under axial compression, bending, or combined loading. Second, the study does not address the long-term durability of the steel-concrete interface, including corrosion protection and carbonation resistance. Third, the recycled aggregate used in the study was from a single source, and the results may not be generalizable to all recycled aggregate types and sources.

Future research should focus on full-scale column tests under combined axial compression and bending loads, long-term durability studies including corrosion and freeze-thaw resistance, and the development of design equations that account for the recycled aggregate replacement rate. The integration of numerical modeling with experimental validation would further strengthen the design basis for steel tube confined recycled aggregate concrete structures.