Axial Compression Performance of Concrete-Filled Steel Tubular Columns with Steel Fiber Self-Stress Self-Consolidating Concrete

Literature Overview

This paper, published in the Journal of Civil Engineering Management (Volume 34, Issue 2, 2017, pp. 1-4) by Lu Yiyan, Yan Bo, Li Na, and Li Shan from Wuhan University, presents experimental research on the axial compression performance of concrete-filled steel tubular (CFST) columns incorporating steel fiber self-stress self-consolidating concrete (SFSSC). Funded by the Ministry of Education Doctoral Point Special Fund Project (20110141110002), the study tested six short column specimens with varying combinations of initial self-stress and steel fiber volume fraction, analyzing the effects on bearing capacity, stiffness, and deformation capacity. The results demonstrate that initial self-stress significantly enhances bearing capacity and stiffness but reduces deformation capacity, while steel fiber addition mitigates the deformation capacity reduction and improves the confinement effect of the steel tube on the concrete.

Technical Background

Self-Stress Concrete

Self-stress concrete (also known as expansive concrete or self-stressing concrete) incorporates expansive agents that generate internal expansion upon hydration. When this expansion is restrained by the steel tube, it creates beneficial initial compressive stresses in the concrete that can:

Steel Fiber Concrete

Steel fibers added to concrete provide:

Self-Consolidating Concrete

Self-consolidating concrete (SCC) offers:

Combined SFSSC System

The combination of all three properties in a single concrete mix represents an advanced material system designed to maximize the performance of CFST columns. The challenge lies in achieving all three properties simultaneously without compromising workability, strength, or durability.

Experimental Program

Specimen Configuration

Specimen ID Concrete Type Self-Stress Level Steel Fiber Volume Description
CFS1 SFSSC Yes Present Steel fiber + self-stress
CFS2 SFSSC Yes Present Steel fiber + self-stress (different ratio)
CSS1 SSC Yes None Self-stress only
CS1 SC No None Self-consolidating only (control)
CFS3 SFSSC Yes Present Steel fiber + self-stress
CFS4 SFSSC Yes Present Steel fiber + self-stress (different ratio)

Test Parameters

Parameter Range/Values Notes
Column diameter Standard