ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Experimental Study on Contact Thermal Resistance Between Steel Tube and Concrete

Literature Overview

This concise paper by Lu Libing, Qi Hanbing, and Wang Lili (2002), published in Oil and Gas Field Surface Engineering, presents experimental investigation into the contact thermal resistance at the interface between steel tubes and concrete in composite structures. The research was conducted at Daqing Petroleum Institute. Although brief in length (one page), the topic it addresses is fundamental to the thermal analysis of all steel tube concrete (STC) composite members.

Technical Significance of Contact Thermal Resistance

The contact thermal resistance at the steel-concrete interface represents a critical parameter in fire engineering calculations. It quantifies the thermal impedance that exists between the steel tube wall and the concrete core, arising from:

Typical Values and Influencing Factors

Factor Effect on Contact Thermal Resistance Engineering Relevance
Concrete density Higher density reduces resistance Denser concrete improves thermal transfer
Steel tube surface finish Rougher surface reduces resistance Surface treatment affects composite action
Concrete slump Higher slump improves filling Workability influences void content
Temperature level Resistance increases with temperature Thermal expansion creates gaps
Tube diameter Larger diameter may increase resistance Scale effect on contact area

Welding and Fabrication Implications

From a steel pipe fabrication standpoint, several considerations arise:

Quality Control Considerations

For engineers responsible for quality assurance of STC members, the following inspection and control measures are recommended:

  1. Verify concrete placement method ensures complete filling, particularly in large-diameter tubes where consolidation challenges increase.
  2. Consider post-placement vibration or internal vibrator access to ensure void-free concrete.
  3. Document tube surface preparation conditions, as this affects both mechanical and thermal interface properties.
  4. For critical fire-resistance applications, consider specifying surface roughening treatments on the tube interior.

Study Insights and Reflections

Although this paper is brief and was published in 2002, the fundamental issue it addresses remains unresolved in many current design codes. Most international fire design codes (Eurocode 4, AISC) assume either perfect thermal contact (zero resistance) or use simplified empirical values. The reality is that contact thermal resistance varies significantly with construction practice, concrete mix design, and service conditions. For engineers working on fire-rated STC structures, obtaining project-specific contact thermal resistance data through testing or using conservative assumptions is essential for accurate fire resistance predictions. This paper, while limited in scope, reminds us that the steel-concrete interface is not a simple boundary condition but a complex zone that deserves careful attention in both design and construction.