ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Interfacial Bonding Performance of Square Steel Tube High-Strength Concrete After High-Temperature Water Spray Cooling

Literature Overview

This paper by Chen Zongping, Zhou Ji, Chen Jianjia, and Zhou Xingyu (2020), published in the Journal of South China University of Technology (Natural Science Edition), investigates the interfacial bonding performance between square steel tubes and high-strength concrete after exposure to high temperatures followed by water spray cooling. The study was supported by the National Natural Science Foundation (51268004), Guangxi Natural Science Foundation Key Project (2016GXNSFDA380032), and the Bagui Scholar Special Fund. The research involved 22 push-out specimens, including 18 water-cooled specimens and 4 natural-cooled specimens.

Core Technical Findings

The study systematically examines how multiple parameters affect the interfacial bond strength after fire exposure and cooling. The push-out test is the standard method for evaluating the steel-concrete interface bond in CFST members, as specified in relevant codes.

Key Experimental Parameters and Results

Parameter Range Studied Effect on Bond Strength
Concrete strength Multiple grades Higher strength increases bond strength
Maximum temperature Multiple levels Bond strength first increases then decreases
Anchorage length Multiple ratios Longer anchorage decreases bond strength
Isothermal duration 60 min vs 90 min 90 min shows recovery compared to 60 min
Cooling method Water spray vs natural Water spray reduces ultimate and residual bond strength

Bond Strength Behavior After Water Cooling

The study reveals a complex but important pattern: after high-temperature exposure followed by water spray cooling, the bond strength initially increases with temperature (up to a certain threshold) and then decreases at higher temperatures. This non-monotonic behavior is attributed to:

  1. At moderate temperatures (up to approximately 400-500°C), thermal expansion of the steel tube may compress the interface, increasing frictional resistance.
  2. At higher temperatures (above 500-600°C), the concrete undergoes significant strength degradation, thermal cracking, and potential spalling, which overwhelms any compressive benefit.
  3. Water spray cooling introduces thermal shock, creating additional micro-cracks at the interface due to differential thermal contraction rates between steel and concrete.

Metallurgical and Material Science Analysis

From a materials science perspective, several mechanisms govern the post-fire interface behavior:

Welding and Fabrication Implications

For square steel tube CFST members subjected to fire and subsequent cooling:

  1. Corner weld integrity: Square tubes have corner welds (or formed corners) that are critical structural details. Under thermal cycling, these welds experience complex stress states that may lead to cracking or fatigue damage.
  2. Post-fire inspection: After a fire event, the steel tube welds should be inspected using non-destructive testing (MT or PT) to detect any thermal-induced cracking.
  3. Residual stress interaction: The residual stresses from welding interact with thermal stresses from fire exposure. In the heat-affected zone (HAZ) of welds, the material may have reduced toughness, making it more susceptible to thermal shock damage.
  4. Repair considerations: If post-fire inspection reveals weld damage, repair welding must account for the altered material properties in the thermally affected zone. Preheating and controlled cooling rates are essential.

Quality Control Recommendations for Post-Fire Assessment

Inspection Method Purpose Timing
Visual inspection Detect spalling, cracking, deformation Immediately after fire
Magnetic particle testing (MT) Detect surface cracks in welds After cooling to ambient
Ultrasonic testing (UT) Detect internal defects in welds After cooling to ambient
Hardness testing Assess HAZ condition After fire event
Push-out testing Evaluate residual bond strength After structural assessment

Engineering Practice Integration

The study's proposed formulas for ultimate bond strength and residual bond strength provide engineers with quantitative tools for post-fire structural assessment. The key engineering implications include:

Study Insights and Reflections

This research addresses a practically important scenario: the condition of CFST members after a fire has been extinguished by water spray, which is the standard fire suppression method in most buildings and industrial facilities. The finding that water-cooled specimens have lower ultimate and residual bond strength but greater energy dissipation capacity is counterintuitive yet physically reasonable. The reduced bond strength results from thermal shock damage, while the greater energy dissipation may reflect the creation of friction surfaces through partial debonding. For engineers responsible for post-fire structural assessment and repair, this paper provides the quantitative basis for evaluating whether a CFST member can remain in service or requires intervention. The proposed bond strength formulas should be validated against additional experimental data from different steel grades and concrete compositions before widespread application. Future research should also consider the effect of fire protection systems (such as intumescent coatings or water mist systems) on the interface behavior, as these systems modify the thermal exposure history experienced by the steel tube and concrete.