ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Nonlinear Dynamic Analysis of Progressive Collapse in Steel Tube Concrete Frame-Core Tube Hybrid Structures

Literature Overview

The paper by Wei Guoqiang, Zheng Long, Wang Wenda, and Song Zilong from Lanzhou University of Technology and Tianshui Normal University (2019), funded by the National Natural Science Foundation of China (51268038), the Gansu Science and Technology Support Program (1604FKCA107), and the Gansu Higher Education Research Project (2018A-079), presents nonlinear dynamic analysis of progressive collapse in a 33-story steel tube concrete (SRC) frame-core tube hybrid structure. Published in the Journal of Seismological Engineering (Vol. 41, No. 3, pp. 581-587), this study employs ABAQUS with fiber beam elements and layered shell elements, utilizing a custom material constitutive subroutine (iFiberLUT).

Core Technical Content

The study investigates the progressive collapse mechanism of a 33-story SRC frame-core tube hybrid structure under local member failure scenarios. The analysis considers column failures at floors 1, 17, and 33, as well as core tube wall failures at the same levels.

Analysis Methodology

Analysis Parameter Specification
Software ABAQUS
Structural model 33-story SRC frame-core tube hybrid
Element types Fiber beam elements (columns/beams) + Layered shell elements (core walls)
Material model Custom subroutine iFiberLUT (fiber-based constitutive model)
Failure scenarios Column failure at floors 1, 17, 33; Core wall failure at floors 1, 17, 33
Analysis type Nonlinear dynamic (time-history)
Key response metrics Vertical displacement, displacement oscillation, load redistribution

Key Findings and Analysis

Displacement Response by Failure Location

Failure Location Maximum Vertical Displacement Oscillation Amplitude Relative Severity
Floor 33 (top) Largest Most pronounced Most severe
Floor 17 (mid) Moderate Moderate Moderate
Floor 1 (base) Smallest Least pronounced Least severe

The finding that top-floor failures produce the largest displacement response is counterintuitive but physically explainable: when a top-floor member fails, the entire structure above the failure point (including the failed member's own mass) must be supported by the remaining structure below. The dynamic amplification is greatest because the inertia forces from the upper mass are not restrained by any upper structure.

Column Failure vs. Core Wall Failure

Comparison Column Failure Core Wall Failure
Vertical displacement Larger Smaller
Oscillation More pronounced Less pronounced
Core tube effect Minimal Minimal
Membrane effect Enhanced by core tube Enhanced by core tube