Nonlinear Dynamic Analysis of Progressive Collapse in Steel Tube Concrete Frame-Core Tube Hybrid Structures
Literature Overview
The paper by Wei Guoqiang, Zheng Long, Wang Wenda, and Song Zilong from Lanzhou University of Technology and Tianshui Normal University (2019), funded by the National Natural Science Foundation of China (51268038), the Gansu Science and Technology Support Program (1604FKCA107), and the Gansu Higher Education Research Project (2018A-079), presents nonlinear dynamic analysis of progressive collapse in a 33-story steel tube concrete (SRC) frame-core tube hybrid structure. Published in the Journal of Seismological Engineering (Vol. 41, No. 3, pp. 581-587), this study employs ABAQUS with fiber beam elements and layered shell elements, utilizing a custom material constitutive subroutine (iFiberLUT).
Core Technical Content
The study investigates the progressive collapse mechanism of a 33-story SRC frame-core tube hybrid structure under local member failure scenarios. The analysis considers column failures at floors 1, 17, and 33, as well as core tube wall failures at the same levels.
Analysis Methodology
| Analysis Parameter | Specification |
|---|---|
| Software | ABAQUS |
| Structural model | 33-story SRC frame-core tube hybrid |
| Element types | Fiber beam elements (columns/beams) + Layered shell elements (core walls) |
| Material model | Custom subroutine iFiberLUT (fiber-based constitutive model) |
| Failure scenarios | Column failure at floors 1, 17, 33; Core wall failure at floors 1, 17, 33 |
| Analysis type | Nonlinear dynamic (time-history) |
| Key response metrics | Vertical displacement, displacement oscillation, load redistribution |
Key Findings and Analysis
Displacement Response by Failure Location
| Failure Location | Maximum Vertical Displacement | Oscillation Amplitude | Relative Severity |
|---|---|---|---|
| Floor 33 (top) | Largest | Most pronounced | Most severe |
| Floor 17 (mid) | Moderate | Moderate | Moderate |
| Floor 1 (base) | Smallest | Least pronounced | Least severe |
The finding that top-floor failures produce the largest displacement response is counterintuitive but physically explainable: when a top-floor member fails, the entire structure above the failure point (including the failed member's own mass) must be supported by the remaining structure below. The dynamic amplification is greatest because the inertia forces from the upper mass are not restrained by any upper structure.
Column Failure vs. Core Wall Failure
| Comparison | Column Failure | Core Wall Failure |
|---|---|---|
| Vertical displacement | Larger | Smaller |
| Oscillation | More pronounced | Less pronounced |
| Core tube effect | Minimal | Minimal |
| Membrane effect | Enhanced by core tube | Enhanced by core tube |
Zhuojin Pipe Fitting Co., Ltd