ZHUOJIN-LOGOZhuojin Pipe Fitting Co., Ltd
Zhuojin Pipe Fitting Co., Ltd
STEEL PIPE · FITTING · WELDING TECHNICAL STUDY

Fire Protection Coating Thickness for Fire-Resistant Steel Concrete Filled Tube Columns

Overview of the Study

The paper by Liu Yixiang, Tong Genzhu, and Zhang Lei, published in the Journal of Zhejiang University (Engineering Science) in 2015, investigates the fire protection coating thickness required for fire-resistant steel concrete-filled tube (CFT) columns under fire conditions. The research was funded by the National Science and Technology Support Program (Grant No. 2012BAJ13B04). The study systematically examines the thermal and structural performance of circular and square CFT columns made with fire-resistant steel under standard fire exposure, providing practical design formulas for fire protection coating thickness determination.

Methodology and Parametric Analysis

The authors employed ANSYS finite element software to simulate the temperature field distribution in both circular and square CFT columns subjected to standard fire temperature-time curves. Multiple fire protection systems were evaluated: thick-type intumescent fire-resistant coatings and cement mortar for circular columns, and autoclaved aerated concrete (AAC) boards with cement mortar for square columns.

Column Type Fire Protection System Parameters Varied
Circular CFT column Thick-type intumescent coating, cement mortar Concrete strength, steel ratio, eccentricity, tube size, fire resistance rating, slenderness ratio, steel grade
Square CFT column AAC board, cement mortar Same as circular

The numerical model accounted for the temperature-dependent mechanical properties of both the fire-resistant steel and the concrete infill. The steel ratio, defined as the ratio of steel cross-sectional area to total cross-sectional area, was varied to capture the influence of steel contribution on fire resistance. The load eccentricity ratio was varied to simulate realistic moment demands on columns in frame structures.

Key Findings on Coating Thickness

The most significant finding of this study is that fire-resistant steel CFT columns require substantially less fire protection coating thickness compared to conventional steel CFT columns. The required coating thickness for fire-resistant steel columns is approximately one-third to one-half of that required for conventional steel columns. This reduction is attributed to the superior high-temperature strength retention of fire-resistant steel, which maintains higher yield strength at elevated temperatures compared to conventional structural steel grades.

The authors developed three practical calculation formulas for determining the required fire protection coating thickness for different column configurations and fire resistance ratings. The calculated results from these fitted formulas showed small errors compared to the full theoretical calculation results, validating the simplified approach for engineering design purposes.

Engineering Practice Integration

The findings of this study have direct implications for structural fire design practice. The reduction in required coating thickness translates into several practical benefits: reduced construction costs associated with fire protection materials and application labor, increased usable building space due to thinner coatings, and reduced overall structural weight. For engineers specifying fire protection systems, the following considerations are relevant:

Study Reflections and Recommendations

This research makes a valuable contribution to the rational design of fire-resistant CFT columns by demonstrating the quantitative benefit of using fire-resistant steel. The development of simplified calculation formulas is particularly useful for practical design, as it eliminates the need for full finite element analysis in routine design situations. However, engineers should note that the study is based on numerical simulation rather than full-scale fire testing, and validation through physical fire tests would further strengthen the confidence in the proposed design formulas. Future research should extend the investigation to include connections between fire-resistant steel CFT columns and beams, as connection behavior under fire conditions is often the governing factor in structural fire design.